Health & Wellness · Lawrence, KS

Custom Medical Device Boxes in Lawrence, KS

Lawrence is home to the University of Kansas — the flagship state university and one of the Big 12's great academic institutions — and a city with a nationally recognized arts community, a vibrant Massachusetts Street commercial district, and a startup ecosystem energized by KU's research output. Lawrence's combination of university energy, artistic vitality, and growing entrepreneurial culture makes it one of Kansas's most commercially distinctive communities. My Custom Boxes serves Lawrence's creative and university-powered business community.

MOQ: 100 unitsFree Shipping to Lawrence2-3 Week Turnaround
📦

Why Lawrence Businesses Choose Us

Free shipping to Lawrence and all Douglas County addresses
KU startup and university packaging accessible from 100 units
Arts and creative brand packaging for Lawrence's vibrant arts community
Massachusetts Street retail packaging for Lawrence's iconic commercial district
100-unit MOQ for Lawrence entrepreneurs and small businesses

Why Choose Our Medical Device Boxes in Lawrence

FDA 21 CFR Part 801 medical device labeling compliance
UDI AIDC barcode and human-readable identifier panel
Intended use and directions for use panel accommodation
510(k) clearance or PMA approval reference information
Lot number, serial number, and expiration date placement
CE marking and international medical device compliance

Medical Device Boxes for Health & Wellness in Lawrence

Medical device boxes serve the home health monitoring and consumer medical device category -- blood pressure monitors, glucose meters, pulse oximeters, digital thermometers, and other consumer medical devices that are regulated by FDA's Center for Devices and Radiological Health (CDRH) under 21 CFR Part 800 series medical device regulations. Medical device packaging has specific regulatory requirements that distinguish it from standard consumer electronics or health product packaging.

FDA Medical Device Labeling Requirements

Medical devices require labeling that complies with FDA 21 CFR Part 801, which mandates: the device's established name and trade name, intended use statement, directions for use adequate for safe and effective use by laypersons, manufacturer name and address, lot number, and for in vitro diagnostic devices, the expiration date and storage requirements. Device packaging cannot make claims that are not supported by the device's FDA clearance or approval.

UDI (Unique Device Identifier) Labeling

The FDA's Unique Device Identification (UDI) system requires most medical devices to bear a UDI on their label and in an FDA database. The UDI consists of a Device Identifier (DI) that identifies the labeler and device, and a Production Identifier (PI) that provides lot/batch number, serial number, and expiration date. UDI must appear on device packaging in both human-readable text and AIDC (automatic identification and data capture) format such as a linear barcode or 2D datamatrix barcode.

Medical Device Packaging Regulatory Compliance Priority

Medical device packaging is subject to a regulatory framework that places consumer safety through accurate labeling as the paramount priority above brand communication considerations. FDA 21 CFR Part 801 medical device labeling requirements define what information must appear, how it must be presented, and what claims may or may not be made based on the device's cleared or approved intended use. Packaging development for medical devices must begin with regulatory compliance review before any design development commences.

UDI Implementation on Medical Device Packaging

The FDA's UDI requirements create specific packaging engineering requirements: the UDI datamatrix barcode must be printed at minimum size and contrast sufficient for automated reading by hospital and supply chain scanning systems, the human-readable UDI must be printed adjacent to the barcode, and the Production Identifier elements (lot, serial, expiration) must be included in the barcode. UDI print quality must be verified against GS1 print quality standards to ensure scanning reliability in distribution and clinical environments.

Quick Specs

Minimum Order
100 units
Production Time
2-3 weeks
Free Shipping
to Lawrence
Industry
Health & Wellness

Materials

SBS PaperboardArt PaperRigid BoardSpecialty Paper

Finishes

Matte LaminationGloss LaminationAqueous CoatingSpot UV

Industries in Lawrence

E-commerceRetailFood & BeverageHealth & WellnessManufacturing
Get a Free Quote

Affordable sample kits available

Industries We Serve in Lawrence

We provide packaging to a wide range of industries in Lawrence, KS.

E-commerce
Retail
Food & Beverage
Health & Wellness
Manufacturing

Popular Use Cases in Lawrence

Consumer medical device retail packaging
Home health monitoring device packaging
Medical device DTC e-commerce packaging
Professional medical device packaging
Medical device gift packaging

Compliance & Safety

Medical device packaging must comply with FDA 21 CFR Part 801 device labeling. UDI required under 21 CFR Part 830. CE marking required for EU distribution per MDR 2017/745. Performance claims must be consistent with cleared or approved intended use. All medical device packaging should be reviewed by regulatory counsel before production.

Medical Device Boxes in Lawrence — FAQs

What FDA labeling is required on medical device packaging?

FDA 21 CFR Part 801 medical device labeling requires: established name and proprietary name of the device, intended use statement, adequate directions for use, manufacturer name and address (or place of business), lot number or batch code, and for in vitro diagnostic devices, expiration date, storage requirements, and performance specifications. UDI in human-readable and AIDC format is required for most Class I, II, and III devices.

What is a UDI and how does it appear on packaging?

The Unique Device Identifier (UDI) consists of a Device Identifier (DI) that identifies the specific device version and labeler, and a Production Identifier (PI) that includes lot/batch code, serial number, and expiration date. The UDI appears in both human-readable format (text readable by people) and AIDC format (machine-readable barcode or 2D datamatrix). The specific format is determined by GS1 standards for medical device identification.

Can medical device packaging make FDA-cleared performance claims?

Medical device packaging may make performance claims that are supported by the device's 510(k) clearance or PMA approval and are consistent with the cleared intended use. Claims that go beyond the cleared intended use are off-label claims that FDA may not permit on labeling. All medical device performance claims should be reviewed against the device's FDA clearance documentation before packaging production.

What CE marking requirements apply to medical device packaging?

EU Medical Device Regulation (MDR) 2017/745 CE marking requirements for medical device packaging: CE mark, Notified Body number (for Class IIa and above), unique device identifier (UDI-DI), lot number, manufacturer name and address, and for single-use devices, the single-use symbol. Packaging must carry these elements for devices distributed in EU member states.

What is the minimum order for custom medical device boxes?

Our minimum order is 100 units for custom medical device boxes. UDI barcode placement and print quality specification guidance is included in the standard setup process for medical device packaging programs.

Do you serve Lawrence's KU startup and university community?

Yes. KU-connected startups and research businesses use our custom packaging with our startup-accessible 100-unit minimum.

What Douglas County areas do you deliver to?

We deliver free to Lawrence, Eudora, Baldwin City, and all surrounding Douglas County communities.

Do you serve Lawrence's Massachusetts Street retail community?

Yes. Mass Street's boutique retailers, restaurants, and creative businesses use our premium retail boxes and branded packaging.

How long does delivery take to Lawrence?

Production is 10–14 business days from proof approval, then 2–3 days ground shipping to Lawrence.

Ready to Order Custom Medical Device Boxes in Lawrence?

Get a free quote with competitive pricing, free shipping to Lawrence, and 2-3 week turnaround.